EEG Source Localization with High-Resolution 40-Tissue Head Models: A Comparative Study with MEG during Photic Driving

While MEG source localization pipelines often employ head models of one single compartment with homogeneous conductivity, researchers and clinicians use at least 3 different layers in head models for EEG source localization. Recent AI-based segmentation makes it possible to generate individualized head models with 40 high-resolution, non-nested tissues. We present a pipeline that can make use of,…

A recent study examines the effectiveness of high-resolution, 40-tissue head models for EEG source localization compared to traditional MEG models during photic driving. While MEG often utilizes single-compartment head models with uniform conductivity, EEG research employs models with up to three layers. Recent advancements in AI enable the creation of individualized 40-tissue models with high resolution.

The researchers designed a pipeline utilizing the boundary element fast multipole method (BEM-FMM) to compute transcranial electric stimulation (TES) solutions on the 40-tissue geometry. This approach calculates EEG leadfields reciprocally and runs efficiently on a single workstation, requiring around 4.5 minutes per EEG channel for a mesh of approximately one million elements with a relative residual of 1e-4.

The pipeline was applied to six participants undergoing intermittent photic stimulation at half their individual alpha peak frequency. The EEG source localizations from the 40-tissue and 5-layer models were compared to each other and MEG localizations recorded simultaneously. The two models demonstrated highly consistent EEG source localizations, with a weighed relative difference below 3%.

Additionally, synthetic EEG topographies generated by both models showed close agreement, with differences scaling linearly with the angle between source orientations in fixed-orientation models. These findings underscore the practicality and robustness of 40-tissue models for EEG source localization, particularly in cases where nested geometries cannot accurately represent anatomy, such as in infants or patients with skull defects, injuries, or tumors.