SCKit Keeps Targeting Unpatched ScreenConnect
Huntress detected a new spike in SCKit activity on November 13, affecting 205 hosts across 41 organizations. ConnectWise says attacks against on-premises ScreenConnect environments are still being reported where identified third-party extensions remain enabled and the software has not been updated. That combination leaves a useful path open. Huntress and Blackpoint Cyber suspect unknown actors of…
On November 13, Huntress observed a surge in SCKit activity affecting 205 hosts across 41 organizations. ConnectWise reported ongoing attacks targeting on-premises ScreenConnect environments, where third-party extensions remained enabled and the software was unpatched. Huntress and Blackpoint Cyber attributed the unauthorized access to an authentication vulnerability in RMM+ versions 1.0.31 and 1.0.32, enabling the deployment of SCKit, a toolkit designed to traverse relationships between customer devices, MSP technicians, and managed networks.
The critical ScreenConnect client flaw, CVE-2026-84869, is a remote code execution vulnerability that permits file transfer and execution without authorization in active remote sessions. The attack sequence leverages a routine technician support action, with the malicious code attempting to execute on the technician's workstation during a support session.
Compromising the technician's workstation could expose additional managed networks to SCKit's capabilities. ScreenConnect technicians are advised to run version 26.6.5 or later, which addresses CVE-2026-84869. ConnectWise recommends disabling five third-party extensions (Labtech Plus, RMM Plus, RMM+, RMM Plus Password Link, and RMM+ Password Link) in 400 partner environments where they remain enabled and ScreenConnect is unpatched.
However, ConnectWise cautions that disabling extensions and updating software will not remove existing access or persistence established by the attacker. Teams must separate their workstreams: first eliminate the vulnerable configuration and then investigate whether the environment or managed endpoints were already compromised. Huntress identified a new ScreenConnect client hosted at 185.241.211[.]197, associated with the bulletproof hosting provider 1337 Services GmbH.
A rogue ScreenConnect client persisted as a service named Windows Update Agent, executing UpdateConnect.ClientService.exe with LocalSystem privileges. Operators should keep the five extensions disabled, update ScreenConnect to the latest supported version, and verify that all technician clients are at least version 26.6.5. Investigation of potentially compromised machines and removal of any discovered access or persistence is crucial.