Urgent.News

What's breaking now, across thousands of outlets.

Finance & Markets

Three counting mistakes that put you in the wrong temperature bucket (checked on 1,153 resolved market-days)

Daily-high temperature markets look simple: one airport, one day, one number. But the market does not resolve on "how hot it was." It resolves on a specific set of airport reports, read by a specific rule. Count the reports a little differently and you land one bucket away, with a number that looks perfectly reasonable. I rebuilt the daily high for every city with a Polymarket daily-high market…

Counting mistakes in temperature markets can lead to being placed in the wrong temperature bucket. This issue is traced to three errors made during the analysis of Polymarket daily-high markets from 17 October to 16 November 2026. The analysis covered 1,153 city-days across 48 cities by comparing the calculated daily high with the actual range resolved by the market.

1. The first error was counting only the top-of-the-hour reports. Many airports outside the United States publish routine reports every 30 minutes instead of hourly. These half-hour reports were missed if the day's peak temperature occurred during a half-hour report. After correcting this mistake, 51 city-days were included, increasing the count from 1,102 to 1,153 (95.6%).

2. The second error involved including special reports (SPECI) from US airports. US airports publish hourly routine reports, but in between, they also issue special reports when conditions change quickly. These special reports, which can carry higher temperatures than routine reports, were not initially counted. After including these reports, 7 additional errors were corrected, and the count increased to 1,146 (99.4%).

3. The third error was truncating instead of rounding the temperature values. The common explanation for temperature reporting suggests truncation, where 10.9 would be rounded down to 10. However, the analysis tested this theory on the same days. Using the 0.1 °C value from the report remarks, converting to Fahrenheit for Fahrenheit markets, and rounding half up to a whole degree resulted in 1,153 of 1,153 city-days matching.

Truncation, on the other hand, placed the number in the wrong range on 59 city-days, or about one day in twenty. This discrepancy was concentrated at airports that report whole-degree temperatures, as the two rules gave the same answer at those airports.

Written by urgent.news from Dev.to's reporting — not their text. Machine-written — may contain errors; check the original before relying on it.

Read the original at dev.to →

More in Finance & Markets

Monday's ETF with Unusual Volume: LST

The Leuthold Select Industries ETF is seeing unusually high volume in afternoon trading Monday, with over 327,000 shares traded versus three month average volume of about 79,000.

More from Monday 16 November →