Pollution Risk from Overboard Pipes Routed Through Fuel Oil Tanks

There have been two more pollution incidents arising from a similar arrangement. In both cases, an Oil Discharge Monitoring Equipment (ODME) overboard discharge pipe was routed through a bunker fuel tank before terminating at the ship’s side. Although all three incidents involved tankers, the recurrence of this failure mode across unrelated vessels highlights a broader ...

Two recent pollution incidents were caused by Oil Discharge Monitoring Equipment (ODME) overboard discharge pipes routed through bunker fuel tanks. In both cases, the section of the pipe located within the bunker tank failed, allowing fuel oil to escape directly into the sea. Despite the overboard valve being closed and the removable spool piece removed, the pipe continued to leak fuel oil.

The incidents occurred on tankers, but the broader risk is significant, as seemingly isolated overboard piping can create a direct pathway between an oil-containing tank and the sea if the pipe loses integrity. The failure modes differed, with one case due to corrosion and wastage and the other due to a crack from original construction.

Once the pipe wall lost integrity inside the bunker tank, it became an uncontrolled pollution pathway. Overboard pipes routed through bunker or cargo oil tanks present a single-point failure risk with potential pollution consequences. Such pipes may be exposed to both water and heated fuel oil, making them susceptible to corrosion, wastage, vibration, thermal cycling, and local stress concentrations.

Inspection of pipe sections within fuel or cargo tanks can be challenging due to difficulty in access and examination. Therefore, Members and ship managers should review overboard piping arrangements across their fleets, particularly any overboard pipe that passes through a bunker or cargo oil tank. They should identify vulnerable arrangements, inspect the complete pipe length within the tank, reassess inspection limitations, review isolation arrangements, and consider alternative pipe routing.

Retrofit modifications and design considerations should be explored, especially during the construction stages of newbuildings. Any identified issues should be reported promptly to the vessel’s Classification Society, and repairs and modifications should be carried out under their approval and supervision. Interim risk controls, such as limiting maximum tank filling levels, may be considered where vulnerable arrangements remain in service.

Ship-specific contingency plans should also address emergency isolation measures and response procedures in case of leakage.