  "id": 22628837,
  "title": "Modelling a PCNL Instrument Set as Structured Data in a Product Catalogue",
  "url": "https://urgent.news/2026/11/29/modelling-a-pcnl-instrument-set-as-structured-data-in-a-product",
  "topic": "tech",
  "section": "Tech",
  "published": "2026-11-29T17:56:30.000Z",
  "source": {
    "name": "Dev.to",
    "slug": "dev-to",
    "url": "https://dev.to/spgmedisafe/modelling-a-pcnl-instrument-set-as-structured-data-in-a-product-catalogue-18da"
  },
  "original_language": null,
  "account": "Medical device catalogues typically display a PCNL instrument set as a single line of text, which works well for marketing materials but poses challenges when ordering systems require verification of component compatibility. To address this, a structured data model can be employed to accurately represent the set's components and their specifications. A typical set comprises five distinct groups, each utilizing its unique size unit: access needle (gauge and length in cm), guide wire (diameter in inches and length in cm), dilators (French range and step size), working sheath (French size and length in cm), and grasps (jaw type and working length in cm). A simplified schema could include fields such as set_code (PCNL-STD-01), component type, gauge (for needles), diameter and coating (for guide wires), French size (for dilators and sheath), jaw type and working length (for grasps), and a single_use flag. By converting the component specifications into structured fields, the system can enforce validation rules to ensure compatibility. For instance, the guide wire diameter must be able to pass through the needle and dilators, and the sheath's French size must match the largest dilator's size. Additionally, the single_use flag aids in proper invoicing, storage, and shipping procedures for both reusable and sterile single-use components. This approach not only mitigates returns resulting from size mismatches but also facilitates side-by-side comparisons of quotations from various suppliers when creating quotes.",
  "summary": "Medical device catalogues often list a PCNL instrument set as one line of text. That is fine for a brochure, but it breaks down when a distributor's ordering system needs to check that the parts actually fit together. Here is a simple way to model the set as structured data. The component groups A typical set has five groups, and each uses its own size unit: Access needle: gauge and length in cm…",
  "summary_source": "publisher",
  "key_points": [
    "PCNL instrument set modeled as structured data for product catalogues",
    "Five component groups with unique size units: needle, wire, dilators, sheath, grasps",
    "Structured schema enables compatibility validation and invoicing accuracy"
  ],
  "editors_take": null,