  "id": 17507,
  "title": "TB 26-04 Webbings for Use in Elevated Oxygen Environments",
  "url": "https://urgent.news/2026/07/31/tb-26-04-webbings-for-use-in-elevated-oxygen-environments",
  "topic": "science",
  "section": "Science",
  "published": "2026-07-31T19:05:25.000Z",
  "source": {
    "name": "NASA",
    "slug": "nasa",
    "url": "https://www.nasa.gov/centers-and-facilities/nesc/tb-26-04-webbings-for-use-in-elevated-oxygen-environments/"
  },
  "original_language": "en",
  "account": "Flammability tests of commercial-off-the-shelf webbings for use in elevated oxygen environments were conducted by NASA's Johnson Space Center and the Mars Campaign Office, with support from the NASA Engineering and Safety Center. The tests were performed on a webbing composed of 60% Kevlar®/40% polybenzimidazole (PBI) at 37% oxygen and 8.2 psia, which is anticipated for future lunar and Martian missions. The natural version of this webbing passed NASA-STD-6001B Test 1 using a surface ignition in a J-configuration. Offgassing data for the natural webbing is also provided. These results indicate that the webbing may be suitable for softgoods applications, although further testing is needed to validate performance and wear characteristics in the full configuration. The elevated oxygen environment increases the risk of flammability, emphasizing the need for improved fire-resistant materials. The strategy, implemented by the NESC, aims to ensure materials meeting NASA flammability requirements are available for aerospace applications.",
  "summary": "Flammability test results for commercial-off-the-shelf webbings that meet NASA flammability requirements are reported for use in elevated oxygen environments anticipated for future lunar and Martian missions. Testing demonstrated that a webbing composed of 60% Kevlar®/40% polybenzimidazole (PBI) from Sturges Manufacturing Company, Inc., specifically the natural version, passed flammability…",
  "key_points": [
    "NASA tests webbing flammability in elevated oxygen environments",
    "60% Kevlar/40% PBI webbing passes ignition test at 37% oxygen",
    "Further testing needed to validate performance in full configuration"
  ],
  "editors_take": null,
  "illustration": null,
  "coverage": {
    "outlets": 1,
    "also_reported_by": []
  },
  "ai_generated": true,
  "disclaimer": "Summaries, key points and the editor’s take are written by software from other outlets’ reporting and may contain errors — always check the linked original."
}